Sysmex Nederland
Menu

PS-10

Description

The PS-10 automates cocktail making and sample preparation. The system is compatible with virtually all antibody, cocktail, PBS, lysis and fixation reagent suppliers. Perhaps the incubation timer will become redundant, but more evident is the fact that pipetting errors are prevented. A professional who can fully concentrate on the core tasks. That's what the PS-10 is all about.

Standardize your sample preprocessing process
Inside the PS-10, the manual work is performed by a robotic arm. The pipetting work is carried out with precision by the built-in syringes. This interaction ensures more accuracy and therefore less variability in your results. The reliability of this is guaranteed by a QC module in the software.

Create your own protocols
Many labs follow the guidelines or use Laboratory-Developed Tests. Washing cells and adding antibodies are routine steps in these processes. As different as the protocols and panels might be, you can easily program them in the PS-10 software.

An efficient workflow
The PS-10 reduces the time that technicians spend on sample preparation. The unique integration with the Rotolavit II-S cell washing centrifuge contributes to this. As a result technicians can truly focus on the interpretation of the flow cytometry results. Not only will your specialists be relieved, the entire process will also be less prone to errors.

Traceability
All proceedings are recorded in the PS-10 software. Each sample handling, such as the added antibody or the incubation time, can be found in a report. In addition, the software records the lot number and shelf life of all antibodies and reagents. This eliminates the need to sign lists and keep track of other administrative matters, hereby contributing to full traceability in your lab.

Specifications
User-programmable procedures lyse no-wash, lyse-wash, pre-lyse (bulk), intracellular staining and custom sequences
variables: sample volume, antibody volumes, cocktail volume, lyse volumes, buffer volumes, incubation times
Sample and reagent volume ranges sample: 50 μL or 100 μL in fixed volume mode or threshold mode; 20 μL – 100 μL in variable mode, adjusted based on the sample WBC count; either via autosampler or open tube positions
antibodies: 4 μL – 100 μL, either single clone vials or cocktail vials
lyse/buffer solutions: 450 – 2,000 μL, configurable
Reagent capacity system fluid: (DI H2 O) 9 L
waste: 9 L
lyse/buffers: 4 x 500 mL and 2 x 125 mL
antibody reagents: positions for up to 90 standard vials
peltier cooling: 2 C – 8 C for up to 30 Sysmex standard and cocktail vials
Sample tube capacity 50 primary sample tubes simultaneously via autosampler
up to 48 daughter tubes via 2 racks: 24-tube fixed-angle rack or 12- or 24-position swing-out rotor
compatible with Hettich Rotolavit II-S automated cell wash centrifuge for automated sample wash steps
System performance

accuracy:

  • sample: 20 μL – 49 μL +/- 10% by volume
  • sample: 50 μL – 100 μL +/- 5% by volume
  • reagent: 4 μL – 19 μL +/- 20% by volume
  • reagent: 20 μL – 100 μL +/- 7% by volume
  • lyse: 450 μL – 2,000 μL +/- 3% by volume

precision:

  • sample: 20 μL – 100 μL CV ≤ 5% by volume
  • reagent: 4 μL – 19 μL CV ≤ 15% by volume
  • reagent: 20 μL – 100 μL CV ≤ 5% by volume
  • lyse: 450 μL – 2,000 μL CV ≤ 3% by volume

throughput:

  • 48 tests/h, two-tube panel, lyse no-wash, includes 10 min stain incubation and 10 min lyse incubation
Weight 129 kg (258 lbs)
Dimensions
H x W x D
PS-10: 106.3 x 75.5 x 94 cm (41.8” x 29.7” x 37”) (excluding keyboard and touchscreen)
optional base: 70.6 x 100 x 114 cm (28” x 39” x 45”)
Power requirements 100 – 240 VAC +/- 10%, 50/60 Hz, 10 A
Environment operating temperature: 150C – 350C (590F – 950F)
operating relative humidity: 10% – 80% non-condensing
noise level: standby mode < 60 dB, run mode < 75 dB peak

 

Contact
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Nederland B.V.

Ecustraat 11

4879 NP Etten-Leur

The Netherlands

+31 (0)76 508 6000

+31 (0)76 508 6086

Sysmex Belgium N.V.

Chaussée de Bruxelles 135A

1310 La Hulpe

Belgium

+32 (0)2 769 7474

+32 (0)2 7697499

Documents

Product documents

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

Rotolavit II-S

Rotolavit II-S

The Hettich Rotolavit II-S automates the washing of your flow cytometry samples

Details
Copyright © Sysmex Europe SE. All rights reserved.