Sysmex Nederland
Menu

XN-2000

The XN-2000 system is a combination of two analysis modules that you can equip with a specified clinical application. In its Rerun & Reflex configuration, it is transformed into a superb solution for basic and extended testing. Because the two modules process rack samples simultaneously, it can accommodate any sample without slowing down. The modules work together perfectly. And you don’t lose any precious time, even with abnormal samples.

With integrated reflex testing, you no longer have to select and reload samples manually. The reflex sampler feeds the samples into the left-hand module automatically and performs the extended measurement. If there are no abnormal samples, it speeds up the system by working on standard samples instead.

Having two modules up and running means you have greater security for daily routines as you always have an integrated back-up solution at your disposal. To enhance the scope of your labs, you can network your XN-2000 with other XNs to create multiple-location installations. This lets you couple specialised and central laboratory units, and increase your service offering. And thanks to our remote services, we can together define levels of support quality, guaranteed service response times and ensure maximum system uptime.

Specifications

Measurement principles

WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin
Aspiration volume     88 µL in whole blood (WB) mode and body fluid (BF) mode
Throughput  up to 200 samples/h
Quality control     XN Check (three levels) and XN Check BF (two levels)
Parameters   XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood   
WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)   
RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)       
PLT-F, IPF, IPF#

With WPC (optional)   
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence        
HPC%, HPC#

Body Fluids with XN-BF   
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
(optional)
Configurations XN-2000 [DIFF]
XN-2000 [WPC]
Contact
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Nederland B.V.

Ecustraat 11

4879 NP Etten-Leur

The Netherlands

+31 (0)76 508 6000

+31 (0)76 508 6086

Sysmex Belgium N.V.

Chaussée de Bruxelles 135A

1310 La Hulpe

Belgium

+32 (0)2 769 7474

+32 (0)2 7697499

Documents

Product documents

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

XN-3100

XN-3100

XN-3100 – Fully scalable to your workload demands

Details
DI-60

DI-60

Fast and accurate, safe and connected!

Details