XN-450
Compact 5-part differential analyser
- Compact 5-part differential analyser
- Single sample analysis in closed or open mode
- Fully integrated IPU including LCD colour touchscreen
- 25 µL aspiration volume in whole blood mode
- Scalable system, optional values and services available
With the XN-450 you can run single samples safely in closed mode. The instrument offers open mode too and comes with a fully integrated IPU, including an LCD colour touchscreen that makes it easy to operate. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future, it can be upgraded by adding new clinical and productivity values, or by opting for further professional services and connecting to our Extended IPU as your demands change.
Specialist solutions for niche diagnostics
The XN-L Series delivers specialist solutions for labs that need to offer niche diagnostics. Dedicated functionalities support the following medical specialties:
- Paediatrics. Low aspiration volume of 25 μL plus the availability of an IG count and HFLC* information with every DIFF analysis.
- Dialysis centres. The RET-He parameter (with RET) and CAPD measurement (with XN-BF) for monitoring patients.
- Neurology wards. Dedicated analysis for various body fluids (with XN-BF) – fast and available 24/7.
- Oncology. Precise and accurate measurement of leucocytopenic samples (with L-WBC) helps, for example, to obtain reliable neutrophil counts during chemotherapy.
*research parameter
Dimensions / weights W x H x D [mm / kg] | XN-450: 450 x 440 x 460 / approx. 35 kg |
Throughput | up to 60 samples/h in WB mode up to 70 samples/h in WB mode with the optional Speed-up licence |
Aspiration volume | 25 µL in WB mode, 70 µL in PD and BF mode |
Analysis parameters | Whole Blood WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG% With RET (optional) RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O Body Fluids with XN-BF (optional) WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF# |
Measurement principles | WBC DIFF/RET: Fluorescence Flow Cytometry WBC: Flow Cytometry RBC/PLT: DC Impedance method with hydrodynamic focussing HGB: Cyanide-free SLS method |
Data storage capacities | Results: 100,000 samples Patient information: 10,000 records Calibration history: 20 times/ module QC files: 99 files including XbarM |
User maintenance | Daily shutdown Weekly cleaning sequence with Cellclean or Cellclean Auto |