XN-9100 Maximum Workload

The XN-9100 Maximum Workload best serves laboratories with a very high workload of EDTA blood sample tubes. You observe significant order entry peaks and need short turnaround times (TAT), while most of your samples are negative.

Ideally, you could do with two different processing lines: one for screening the bulk of the samples as fast as possible and another for analysing those with conspicuous results further.  Looking at your samples, most should have order profiles for cell counting only, while analyses for other work areas (e.g. HbA1c or ESR) should not exceed 20-30% to keep up a smooth and fast workflow.

And if you need to archive your EDTA tubes and/or sort them for subsequent work areas, yet don't need sample pre-sorting or rack optimisation, Maximum Workload is the solution for you.

Specificaties
Measurement principles WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin
Throughput
From 2 modules of XN-10/20 in
combination with SP-50 (H mode):


from 200 samples/h in whole blood (WB) mode,
up to 40 samples/h in body fluid (BF) mode per module,
up to 30 slides/h in standard mode per module,
up to 75 slides/h with the optional high-throughput licence per module
Aspiration volume
XN module:
SP-50 module:

88 μL in whole blood (WB) mode and body fluid (BF) mode
70 μL for smear preparation in auto mode,
38 μL for smear preparation in manual mode
Analysis parameters
Whole Blood

With RET (optional)
With PLT-F (optional)
With WPC (optional)
XN Stem Cells licence:
Body Fluids with XN-BF
(optional)

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV,
P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#
RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O
PLT-F, IPF, IPF#
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#
HPC%, HPC#
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
Sampler unit capacity 25 racks (250 samples) – Start Yard (ST-40) capacity
Integrated optional module DI-60 for digital image analysis
Tube sorter TS-10
Tosoh HLC-723 G11* – automated glycohaemoglobin analyser
Interrliner* – automated ESR reader
Staining protocols (SP-50) May Grünwald – Giemsa, Wright – Giemsa, Wright
Data storage capacities
(XN module)

Results: 100,000 samples
Patient information: 10,000 records
QC files: 99 files (300 plots per file)
Reagent replacement history: 5,000 records
X-bar control (L-J control): 300 plots x 94 files
X-barM control: 300 plots x 5 files
Contact
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Nederland B.V.

Ecustraat 11

4879 NP Etten-Leur

The Netherlands

+31 (0)76 508 6000

+31 (0)76 508 6086

Sysmex Belgium N.V.

Chaussée de Bruxelles 135A

1310 La Hulpe

Belgium

+32 (0)2 769 7474

+32 (0)2 7697499

Explore more

DI-60

DI-60

DI-60 van Sysmex – snel en nauwkeurig, veilig en verbonden!

Details
XN-1000

XN-1000

We stellen u het paradepaardje onder de Sysmex-analysers voor

Details
XN-1500

XN-1500

XN-1500 – Count. Smear. Stain. All-in-one haematology

Details
Copyright © Sysmex Europe SE. All rights reserved.